TX® ( I ) 331 150/250V 10P0.75

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TX® (I) 331  150/250 V fire resistant overall and individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables show a strong protection aganist cross-talk and result into a good compromise between TX® (C) 331 and TCX® (C) 331 cables against external electromegnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

1.   Conductor:
      Stranded bare copper
      Class 2
2.   Insulation: Mica tape + XLPE (cross-linked polyethylene)
     
Optional: Special fire resistant HF 90 (halogen-free compound)
      with INFITTM technology
3.   Individual screen:
      Alu/polyester tape with a tinned copper drain wire
4.   Outer sheath:
      Polyolefin SHF1 (SHF2 on request)
      Colour: orange

 

Marking

I NEXANS I  TX (I) 331  150/250 V  "n x 2 or 3 x s" mm²  90 °C - IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 ww/yy - CE  + metric marking

 

Core identification

  • Core 1 : white
  • Core 2 : blue
  • Core 3 : red
  • Double identification: conductor  and pair

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Conductor flexibility
Stranded class 2
Insulation
HFFR special
Screen
Aluminium-Polyester tape
Drain wire
Tinned copper
Outer sheath
Polyolefin
Sheath colour
Orange

Dimensional characteristics

Dimensional characteristics

Number of pairs
10
Number of triples
-
Conductor cross-section
0.75 mm²
Minimum outer diameter
17.0 mm
Nominal outer diameter
- mm
Maximum outer diameter
21.0 mm
Approximate weight
470 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
150 / 250 (300) V
Max. DC resistance of the conductor at 20°C
52 Ohm/km

Usage characteristics

Usage characteristics

Fire resistant
-
Fire retardant
EN IEC 60332-3-22 (cat A)
Standard
IEC
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close